Features :
• Wide range measurements from 500V to 5000V and up to 1000GO.
• Large digital display with Bar Graph indication and back light.
• Polarization Index measurement (PI).
• imer measurement function.
• Indication of Output voltage and Discharge voltage.
• Auto-discharge function and Voltage output warning function.
• Auto power off and Battery Check.
• Safety standard IEC 61010-1 CAT III 600V.
Specifications :
Range Insulation resistance Voltage measurement 500V 1000V 2500V 5000V AC/DC V Measuring range 0.0 - 99.9MO 100 - 999MO 0.0 - 99.9MO 100 - 999MO 1.00 - 1.99GO 0.0 - 99.9MO 100 - 999MO 1.00 - 9.99GO 10.0 - 99.9GO 0.0 - 99.9MO 100 - 999MO 1.00 - 9.99GO 10.0 - 99.9GO 100 - 1000GO (1TO) 30 - 600V AC/DC [50/60Hz]
Accuracy |±5%rdg |±3dgt |±5%rdg |±3dgt |±5%rdg |±3dgt |±5%rdg |±3dgt |±20%(100GO or more) |±2%rdg |±3dgt
Short Circuit Current 1.3mA approx. -------
Rated test Current 1mA to 1.2mA at 0.5MO load 1mA to 1.2mA at 1MO load 1mA to 1.2mA at 2.5MO load 1mA to 1.2mA at 5MO load ------- Open circuit voltage 500VDC +30% -0% 1000VDC +20% -0% 2500VDC +20% -0% 5000VDC +20% -0% ------- aximum display 999 Counts (1000 counts only at 1000GO) 630
Counts Current consumption About 1000mA (During measurement) 110mA approx. Withstand Voltage Safety standard 5320V AC for 5 seconds IEC 61010-1 CAT III 600V, pollution Degree 2 Power supply DC12V : R14×8 Dimensions 205(L) × 152(W) × 94(D)mm Weight 1.8kg approx. Accessories 7165A (Line probe) 7224A (Earth cord) 7225A (Guard cord) 8019 (Hook type prod) 9159 (Carrying case [Hard]) LR14×8pcs (Alkaline battery size) Instruction Manual Optional 7168A (Line probe with alligator clip) 7253 (Longer Line probe with alligator clip) 8302 (Adaptor for recorder)
Developed by : Shafiul Bashar